SAVE UP TO 50% IN JUST 60 SECS!
Compare free conservatory roof repair quotes from Reading roofers. Covering Caversham, Tilehurst, Whitley, Earley, Calcot, Coley...
Updated: 31 Dec 2025
31 Dec 2025
Emmer Green: Leaking Glass Conservatory Roof on approx. 20 square metres Glass. Minor scratches/etching reducing clarity. Access only via conservatory itself (internal). first noticed during a cold snap.
29 Dec 2025
Southcote: Polycarbonate Roof Leak Investigation on 18m² Polycarbonate. Noise transmission in heavy rain – seek damping options. Neighbour access arranged. Small business owner needs urgent repair.
28 Dec 2025
Fix Noise from Loose Tiles in Wind — Tiled Warm Roof (Lean-to), small roof (8m²) (Emmer Green). Insulation gap causing cold spots. Access via side gate, limited space for tower. noticed while cleaning roof panels. Homeowner preparing to sell.
23 Dec 2025
Polycarbonate Panel Replacement (Gable-front) — Polycarbonate (P-shaped), 14m² (Palmer Park). Capillary action at panel edges due to failed tape. Through garage, internal ladder route. issue highlighted during routine insurance check. Ongoing maintenance request.
20 Dec 2025
Fit Leaf Guards to Outlets in Southcote on about 22m² Box Gutter / Drainage (Victorian) conservatory roof. Issue: Standing water/ponding in box gutter. Access: Over conservatory extension — requires roof ladder.
19 Dec 2025
End Cap Replacement & Reseal — Polycarbonate, larger roof (~14m²) (Tilehurst). Panel slipped under storm load. Rear garden only, narrow ladder access. issue highlighted during routine insurance check.
13 Dec 2025
Lantern Base Seal Renewal — Lantern / Skylight, small roof (12m²) (Emmer Green). Blocked drainage paths within lantern frame. Access only via conservatory itself (internal). Insurance inspection pending.
12 Dec 2025
Lantern Drainage Slot Clean — Lantern / Skylight, larger roof (~24m²) (Kennet Island). Water marks on plastered upstand beneath lantern. Over conservatory extension — requires roof ladder. Insurance inspection pending.
9 Dec 2025
Counter-Flashing Install/Refix — Flashing / Wall Abutment, larger roof (~14m²) (Coley). Split lead causing capillary drip. Steep garden slope complicates ladder setup. first noticed during a cold snap.
4 Dec 2025
Kennet Island: Safety Glass Upgrade (where required) on 16m² Glass. Blown unit with condensation between panes. Scaffold tower likely (two-storey rear).
4 Dec 2025
Southcote: Lantern Sidelight Glass Unit Swap (rear conservatory) on approx. 24 square metres Glass (Edwardian). Blocked drainage slots beneath glazing leading to pooling. Narrow side passage; debris removal tricky. appeared suddenly after recent heatwave. Request from landlord of rental property.
1 Dec 2025
Leak at Glazing Bar — Polycarbonate, approx. 9 square metres (Earley). Panel slipped under storm load. Access via side gate, limited space for tower. Homeowner preparing to sell.
| Job | Basis | Typical Range |
|---|---|---|
| Replace one polycarbonate panel | per panel | £152 - £303 |
| Replace one glass roof unit | per unit | £253 - £505 |
| Box gutter clean & reseal | job | £121 - £253 |
| Lead flashing renewal | job | £202 - £404 |
| Replace glazing bar gaskets | per bar | £81 - £152 |
| End cap replacement set | set | £61 - £121 |
| Internal reseal against leaks | job | £152 - £303 |
| Full polycarbonate roof re-sheet | 20m² | £1,818 - £2,828 |
| Lightweight tiled roof conversion | 20m² | £6,060 - £10,100 |
| Add insulation & plaster ceiling | 20m² | £1,515 - £2,525 |
Guide prices only. Actual quotes vary by access, substrate condition, detailing, and material choice.
| Type | Number | Share |
|---|---|---|
| Box Gutter / Drainage | 3 | 10% |
| Tiled Warm Roof | 4 | 13% |
| Gaskets & Trims (uPVC) | 4 | 13% |
| Polycarbonate | 8 | 27% |
| Glass | 5 | 17% |
| Flashing / Wall Abutment | 4 | 13% |
| Lantern / Skylight | 2 | 7% |
(Number of quote requests received in and around Reading over the previous 12 weeks)
31 Dec 2025
Minor draught/leak on Glass addressed by repacking and resealing beads. Autumn/Winter weather likely contributed.
| Step | Description | Minutes |
|---|---|---|
| Check | Inspect beads; identify gaps. | 15 |
| Repack | Adjust packers; refit beads. | 22 |
| Seal | Run neat perimeter bead. | 13 |
Estimated time: ~50 minutes
23 Dec 2025
Failed/loose end caps on Polycarbonate allowing wind-driven rain in. New caps installed with compatible seals; edges cleaned and sealed. Autumn/Winter weather likely contributed.
| Step | Description | Minutes |
|---|---|---|
| Remove & clean | Remove damaged caps; clean edges and bar ends. | 17 |
| Fit new caps | Install caps with fresh gaskets; ensure tight fit. | 21 |
| Seal & test | Seal interfaces; quick hose test. | 17 |
Estimated time: ~55 minutes
We always recommend hiring qualified Reading conservatory roof specialists for leaks, replacements or structural issues. For confident homeowners with the right tools and PPE, small maintenance jobs such as clearing gutters, replacing end caps, or resealing trims may sometimes be attempted yourself.
We’re still gathering supplier information for Reading.
In the meantime, you can search for conservatory roof suppliers in Reading on Google Maps.
Note: Listings are for convenience only; we do not recommend or endorse any individual supplier.
Slough - 16.9 miles
28 Dec 2025
Oxford - 23.8 miles
31 Dec 2025
Watford - 28.9 miles
31 Dec 2025